Methods: This technique was used in twenty five patients (28 fracture lines). The access to the fractures was via extraoral approach (through existing scars or incisions). The follow up was in a week,two week, one and six months and one year after the surgery regarding the occurrence of malocclusion or infection.
Results: From the patients who underwent surgery, only one malocclusion and no case of infection was observed.
Conclusions: This method can be used as reliable and efficient method for treatment of mandibular fracture.this method can be used instead of single miniplate or reconstruction plate in clinical situations that need both intensive fixation and rigidity.