Kuraray Medical Inc. has developed a core build-up system consisted of a new dual-curing composite resin "NDC-100" and a new one bottle self-etching bond system "MTB-200". "NDC-100" is a two-paste formula composed of methacrylate monomers, initiators, new polymerization accelerator and fillers delivered in an auto-mix dual-syringe. "MTB-200" is a single-component and light-cured single-step bonding system which contains an adhesive phosphate monomer (MDP) and chemical initiator to work effectively with "NDC-100" in self-curing mode.

Objectives: The purpose of this study was to compare tensile bond strength of the core build-up system "NDC-100" and "MTB-200" with those of other commercially available core materials (CLEARFIL DC CORE AUTOMIX; Kuraray medical, LuxaCore Dual; DMG, Rebilda DC; VOCO, ESHTELITE-CORE QUICK; Tokuyama Dental, Unifil Core EM; GC).

Methods: Bovine dentin surfaces were treated with core build-up systems according to each manufacturer's instructions. All the specimens were immersed in water at 37˚C for 24 hours prior to performing the tensile bond strength test.

Results: Table. 1 showed the tensile bond strength of each core build-up systems to bovine dentin.

Table. 1                                                                                                                                MPa(SD)

Core build-up system

Curing condition; Composite/Bond

Core material

Bond

Bonding system

light/light

self/self

NDC-100

MTB-200

One bottle

One step

18.5(6.4)

12.4(2.8)

DC CORE

AUTOMIX

DC BOND

Two bottle

One step

17.6(5.1)

7.5(1.3)

LuxaCore Dual

Contax

Three bottle

Two step

9.9(2.7)

2.3(2.2)

Rebilda DC

Futurabond DC

Two bottle

One step

6.2(3.0)

1.3(1.2)

ESTHELITE

CORE QUICK

ESTHELITE

CORE QUICK BOND

Two bottle

One step

17.3(6.4)

10.2(5.5)

Unifil Core EM

Unifil Core EM Self etching Bond

Two bottle

One step

12.3(3.2)

7.2(4.1)

Conclusions: New core build-up system "NDC-100" and "MTB-200" showed the highest bond strength to bovine dentin both in light/light and self/self mode among the evaluated core build-up systems.


IADR/AADR/CADR General Session
2011 IADR/AADR/CADR General Session (San Diego, California)
San Diego, California
2011
1110
Dental Materials 1: Adhesion - Bond Strength Testing and Mechanisms
  • Suzuki, Kenji  ( KURARAY MEDICAL INC, Okayama, N/A, Japan )
  • Kawana, M.  ( KURARAY MEDICAL INC, Okayama, N/A, Japan )
  • Takei, M.  ( KURARAY MEDICAL INC, Okayama, N/A, Japan )
  • Kawashima, M.  ( KURARAY MEDICAL INC, Okayama, N/A, Japan )
  • Poster Session
    Adhesion to Dental Tissues II
    03/17/2011