IADR Abstract Archives

Bond Strength of Self-adhesive Resin Cement to Tooth Structure/Ceramics

Objectives: Bond strengths (BS) of two self-adhesive resin cements (RelyX Unicem 2 Automix, RU2; SpeedCEM, S) to human ground enamel (GE) and dentin (D), zirconia (Lava, L) and lithium disilicate (IPS e.max CAD, EC) were tested. Methods: Specimens of GE, D, L, and EC were ground through 600-grit SiC paper. L was then sandblasted with 50 μm alumina. EC was treated with HF gel etchant for 20s, rinsed, and then ceramic primer (Monobond Plus) was applied. BS was tested using indirectly cemented cylinders of composite (TPH3) with the Ultradent shear BS test method. Both light-cured (LC) (Demi LED) and self-cured (SC) modes were evaluated. Both cements were protected from oxygen inhibition during SC by a coating (Oxyguard II). Testing was performed after 24h storage in water at 37°C. Data were analyzed statistically using analysis of variance and Fisher's PLSD at the 0.05 level of significance. Results: Means and standard deviations are shown in the table. Data were analyzed by analysis of variance at the 0.05 level of significance.  Means with the same letters are statistically the same.

Cement

Cure

Substrate

Bond Strength, MPa

RU2

LC

GE

17.5(3.1)d

S

 

 

13.6(1.6)b

RU2

SC

 

10.1(1.6)

S

 

 

14.7(3.4)be

RU2

LC

D

18.7(1.3)d

S

 

 

11.8(1.4)

RU2

SC

 

13.5(2.0)a

S

 

 

13.8(1.7)ae

RU2

LC

EC

36.5(3.2)

S

 

 

34.1(5.2)

RU2

SC

 

32.5(1.9)

S

 

 

28.0(5.1)

RU2

LC

L

30.9(4.8)

S

 

 

14.1(2.7)c

RU2

SC

 

17.9(2.1)

S

 

 

13.6(1.7)c

Conclusions: RU2 produced statistically higher BS to L and EC than S when either LC or SC. S and RU2 had equivalent BS when SC to D. RU2 produced statistically higher BS to GE and D than S when LC. SC BS of S to GE was higher than RU2. LC BS of same cements were higher than or equivalent to SC except for S on D. Funded by 3M ESPE.


Division: IADR/AADR/CADR General Session
Meeting: 2011 IADR/AADR/CADR General Session (San Diego, California)
Location: San Diego, California
Year: 2011
Final Presentation ID: 511
Abstract Category|Abstract Category(s): Dental Materials 1: Adhesion - Bond Strength Testing and Mechanisms
Authors
  • Powers, John M.  ( Dental Consultants, Inc, Ann Arbor, MI, USA )
  • Yapp, Ron Arthur  ( Dental Consultants, Inc, Ann Arbor, MI, USA )
  • Malmsten, Anthony  ( Dental Consultants, Inc, Ann Arbor, MI, USA )
  • SESSION INFORMATION
    Poster Session
    Adhesion to Other Materials
    03/17/2011