IADR Abstract Archives

Effect of Pre-etching on the Durability of Bond Strength of Self-etching Adhesives to Ground Enamel

Objectives: To test the hypothesis that previous etching with 37% PA improve bond strength and durability of bonds made with Clearfil SE Bond (SE, Kuraray) and One Up Bond F (OUB, Tokuyama) to ground enamel. Methods: Buccal and lingual enamel of human third molars were ground wet with coarse diamond bur. The adhesives were applied either according to manufacturer’s instructions (20s, CG) or after pre-etching enamel with 37% PA for 10s (EG). Bonded teeth were stored for 24h at 37ºC, sliced and trimmed to a dumbell-shape with a cross-seccional area of 0.8 mm2. The specimens were stored either in water (W) or mineral oil (O) for 24h, 6 months (6M) and 1 year (1Y). After each storage period, specimens were tested in microtensile at 0.5mm/min. Results: Values are MPa ± SD(N). Capital letters compare each condition as a function of time and storage medium (row). Lower cases compare each material as a function of etching within each storage condition (column).

Material

24h

6MW

1YW

6MO

1YO

SE (CG)

30,5±8,3Aa

(10)

22,4±6,3Bb

(8)

23,7±11,0Bb

(10)

30,6±8,2Aa

(6)

32,5±10,5Aa

(9)

SE (EG)

38,5±11,1Aa

(7)

31,4±8,1Aa

(9)

37,9±14,4Aa

(11)

29,6±10,6Ba

(8)

35,5±6,3Aa

(6)

OUB (CG)

17,5±6,0Ac

(8)

23,7±7,5Ac

(12)

18,4±4,8Ac

(9)

19,7±8,4Ac

(7)

30,3±5,5Bc

(7)

OUB (EG)

41,3±7,5Ad

(9)

27,5±10,5Bc

(9)

26,6±6,8Bd

(11)

39,5±9,8Ad

(7)

48,6±11,2Ad

(8)

Multiple-way ANOVA showed that the effect of etching and storage was dependent on the material. Pre-etching with PA improved immediate bond strength for OUB (p<0.05), but not to SE (p>0.05). Pre-etching resulted in sustained bond strength of SE after water storage (p>0.05), but not for OUB (p<0.05) after water storage. Specimens stored in oil maintained bond strength over time (p>0.05). Conclusion: The effects of pre-etching ground enamel with 37%PA on the bond strength and durability of the bonds made with self-etching adhesives are material dependent.

 


Division: IADR/PER General Session
Meeting: 2003 IADR/PER General Session (Goteborg, Sweden)
Location: Goteborg, Sweden
Year: 2003
Final Presentation ID: 862
Abstract Category|Abstract Category(s): Dental Materials: I - Adhesion-Composite Bond Strength
Authors
  • Marquezini, L.  ( University of São Paulo, Bauru, N/A, Brazil )
  • Pereira, Lúcia C. G.  ( Anápolis Dental School - FAEE, Anápolis, N/A, Brazil )
  • Carvalho, Ricardo M.  ( University of São Paulo, Bauru, N/A, Brazil )
  • Tay, Franklin R.  ( The University of Hong Kong, Hong Kong SAR, N/A, China )
  • Pashley, David H.  ( Medical College of Georgia, Augusta, GA, USA )
  • SESSION INFORMATION
    Poster
    Self-etching Adhesive Systems 2
    06/26/2003