Assessment of Novel Intraoral Bisecting Angle Digital Imaging Receptor Holders
Objectives: This study was performed to assess the effectiveness and comfort of novel intraoral digital radiograph receptor devices/holder in obtaining digital intraoral images.
Results: The repeat rate percentage for novel intraoral and conventional holder devices were 8.9% and 18.6%, respectively (p<0.05). The median range of the "comfort data" according to conventional and novel intraoral radiographic receptor holder was 16 mm to 57 mm and 15 mm to 58 mm, respectively. No patients scored more than 74 mm.
Conclusions: The novel intraoral holder exhibited lower percentage of repeat as compared to the conventional holder. Both groups did not cause major discomfort (mild-moderate pain). The use of novel intraoral bisecting angle radiographic receptor holder is however recommended to optimize the repeat rate in certain anatomical challenged patients.