IADR Abstract Archives

Detection of Caries Around Glass Ionomer and Compomer Restorations Using Four Different Modalities

Objectives: The aim of this study was to evaluate the ability of PTR-LUM (The Canary System, CS), laser fluorescence (DIAGNOdent, DD), LED fluorescence (Spectra), and visual inspection (ICDAS II) to detect natural decay around glass ionomer and compomer restorations.
Methods: Twenty seven extracted human molars and premolars, consisting of 10 visually-healthy and 15 teeth with natural cavitated lesions were selected. For the carious teeth, caries was removed leaving some decayed tissues on the floor and wall of the preparation. For sound teeth, 3 mm. deep cavity preps were made and teeth were restored with glass ionomer and compomer materials. 68 sites (4 sites on sound unrestored teeth, 23 sound sites with restorations; 43 carious sites) were selected. CS and DD scans were performed in triplicate at 2, 1.5, 0.5, and 0 mm away from the margin of the restoration (MOR). Spectra images were captured for the entire surface, and dentists blinded to the samples provided ICDAS II scoring.
Results: Canary Numbers (Mean±SE) for healthy and carious sites at 2, 1.5, 0.5, and 0 mm ranged from 18.3±0.7 to 20.1±1.3 and 45±2.4 to 52.2±3.5, respectively. DD peak values for healthy and carious sites ranged from 5±0.9 to 17.2±2.3, and 8.6±1.5 to 19.5±2.8, respectively.
For Canary System the sensitivity/specificity for sites at 2.0, 1.5, 0.5, 0 mm ranged from 0.91-1.0/0.71-0.93.
For DIAGNODent sensitivity/specificity for sites at 2.0, 1.5, 0.5, 0 mm ranged 0.19-0.7/0.14-0.93.
For ICDASII, sensitivity and specificity were 0.35 and 0.52, respectively.
For Spectra, data and images were inconclusive due to signal interference from the restoration.
The intra-operator repeatability for DIAGNODent was 0.971 and The Canary System was 0.988.
Conclusions: CS and DD were able to differentiate between sound and carious tissue at the MOR, but larger variation, less reliability, and poorer accuracy was observed for DD. Therefore, CS has the potential to detect secondary caries around glass ionomer and compomer restorations more accurately than the other investigated modalities.
IADR/PER General Session
2018 IADR/PER General Session (London, England)
London, England
2018
0099
Cariology Research-Detection, Risk Assessment & Others
  • Abrams, Tamara  ( Quantum Dental Technologies , Toronto , Ontario , Canada )
  • Abrams, Stephen  ( Quantum Dental Technologies , Toronto , Ontario , Canada ;  Cliffcrest Dental Office , Toronto , Ontario , Canada )
  • Sivagurunathan, Koneswaran  ( Quantum Dental Technologies , Toronto , Ontario , Canada )
  • Moravan, Veronika  ( VM Stats , Toronto , Ontario , Canada )
  • Hellen, Warren  ( Cliffcrest Dental Office , Toronto , Ontario , Canada )
  • Elman, Gary  ( Cliffcrest Dental Office , Toronto , Ontario , Canada )
  • Amaechi, Bennett  ( University of Texas Health Science Center at San Antonio , San Antonio , Texas , United States )
  • Quantum Dental Technologies provided financial support for part of this project. Cliffcrest Dental Office provided the materials used in this study.
    Oral Session
    Early Detection of Dental Caries With New Technologies
    Wednesday, 07/25/2018 , 09:30AM - 11:00AM