Effect of Flowable Composites on Clinical Results of Direct Restaurations
Objective: The purpose of the prospective randomized clinical study was to compare the clinical performance of the self-etching adhesive system Futurabond DC in combination with the composite GrandiSO and the influence of the additional application of the flowable resin composite GradioSO Heavy Flow after one year. Method: In 50 patients 32 class I and 68 class II cavities were placed with at least two restorations per patient. The adhesive system Futurabond DC was used for all the restorations. In one of the two fillings in each patient, an additional layer of the flowable resin composite GrandioSO Heavy Flow was applied in the entire cavity and separately light-cured. The fillings were placed under rubber dam. All materials were used as recommended by the manufacturer. Two clinicians evaluated the restorations at baseline, two week following placement, and at the six month recall visit according to the modified clinical criteria of Ryge. For this sensitivity, hypersensitivity, marginal discoloration, marginal adaption, recurrent caries, surface, color match, proximal contact and filling integrity were considered. All data were analyzed by Man-Whitney-U-test. Result: After six months 47 patients could be re-examined. All 94 teeth remained vital and did not show any signs of postoperative sensitivity. Marginal adaption code Bravo could be evaluated in one filling (with flowable liner). In five teeth a marginal discoloration was scored as Bravo (three with and two without fowable liner). None of the teeth showed signs of secondary caries. Statistical analysis showed no significant difference between techniques for any of the evaluation criteria (p>0.05, Man-Whitney-U-test). Conclusion: After one year the use of a flowable composite showed no significant impact on the clinical performance of class-I and -II restorations. furthermore, the self-etch adhesive Futurabond DC might be a promising alternative to other systems. This study was supported by Voco GmbH, Germany.
Division: IADR/AMER General Session
Meeting:2014 IADR/AMER General Session (Cape Town, South Africa) Location: Cape Town, South Africa
Year: 2014 Final Presentation ID:1151 Abstract Category|Abstract Category(s):Dental Materials 4: Clinical Trials
Authors
Gernhardt, Christian
( Martin-Luther-University Halle-Wittenberg, Halle, , Germany
)
Michaelis, Mary
( Martin-Luther-University Halle-Wittenberg, Halle, , Germany
)
Schaller, Hans
( Martin-Luther-University Halle-Wittenberg, Halle, , Germany
)
SESSION INFORMATION
Poster Session
Adhesives and Composite Clinical Trials
06/27/2014