Objective:

The study is aimed to compare the diagnostic accuracy of cone beam computed tomography (CBCT) with conventional periapical radiographs as well as intraoperative findings for detecting vertical root fractures(VRF).

Method:

The study include nineteen teeth which were highly suspected as VRF due to clinical presentations. These teeth underwent dental radiography and cone beam computed tomography (CBCT) and flap surgery by periodontist to confirm VRF. One radiologist(A) and one endodontist (B) who did not participated in surgical exploration analyzed these images independently.

Result:

The results were compared with each other and with intraoperative findings. Sensitivity for VRFs of CBCT were 80.00%(A),73.33%(B)respectively;for that of periapical radiographs, the sensitivity were 26.67%(A), 20.00%(B) respectively.

Conclusion:

CBCT is showed to be superior to conventional periapical radiograph in the detection of VRF.

Division: IADR/AMER General Session
Meeting: 2014 IADR/AMER General Session (Cape Town, South Africa)
Location: Cape Town, South Africa
Year: 2014
Final Presentation ID: 412
Abstract Category|Abstract Category(s): Periodontal Research - Diagnosis / Epidemiology
Authors
  • Huang, Ping  ( West China College of Stomatology, Sichuan University, Chengdu, China, Chengdu, , China )
  • Jiang, Hui  ( West China College of Stomatology, Sichuan University, Chengdu, China, Chengdu, , China )
  • Pan, Tao  ( West China College of Stomatology, Sichuan University, Chengdu, China, Chengdu, , China )
  • Wu, Wan  ( West China College of Stomatology, Sichuan University, Chengdu, China, Chengdu, , China )
  • SESSION INFORMATION
    Poster Session
    Periodontal Diagnosis/Epidemiology: Miscellaneous
    06/26/2014